Industrial Fire Precaution Levels (IFPL)

Smokey BearIndustrial Fire Precaution Levels are only implemented on public lands administered by the Fremont-Winema National Forest, Bureau of Land Management’s (BLM) Lakeview District and Sheldon-Hart Mountain National Wildlife Refuge Complex.

The only Lakeview District BLM-managed lands exempt from this order are those within the Klamath Falls Resource Area that are west of the Langell Valley. This area is under the protection of the Oregon Department of Forestry (ODF). Information regarding restrictions that apply to ODF-protected lands may be obtained by calling (541) 883-5681 or visiting the following Web site:  

http://egov.oregon.gov/ODF/FIRE/precautionlevel.shtml

Personal and commercial woodcutters are reminded of their responsibility to stay informed of current IFPLs and all restrictions that apply to activities conducted on public lands. Failure to comply with fire precautionary requirements may result in the issuance of a Violation Notice.

Information on the IFPL or current restrictions may be obtained by calling the Lakeview Interagency Fire Center at 541-947-6259 or visiting its Web site at: http://www.scofmp.org/lifc.shtml.

IFPL RESTRICTIONS

Level I

Under IFPL I, the following fire precautionary requirements are placed on power saw operations: 

  • All power saw exhaust systems must be in good repair and include a screen-type spark arrester of 0.023 inches or less. 
  • All power saw operators must be in possession of the following equipment:
    • A long-handled, round point shovel with a blade not less than eight inches wide; and
    • A pressurized chemical fire extinguisher of not less than eight ounces capacity by weight. 
  • Before refueling a power saw, the refueling spot must be clear of all flammable material, including vegetation. The chainsaw must be restarted only after the operator has moved away from the refueling area. 
  • All power saw operators must stay in the cutting area for one hour after the chainsaw is shut off to watch for fire starts.
Level II

Under IFPL II, the following fire precautionary requirements are placed on power saw operations: 

  • Power saws and welding equipment may not be operated between the hours of 1 p.m.and 8 p.m. 
  • All power saw exhaust systems must be in good repair and include a screen-type spark arrester of 0.023 inches or less. 
  • All power saw operators must be in possession of the following equipment:
    • A long-handled, round point shovel with a blade not less than eight inches wide; and
    • A pressurized chemical fire extinguisher of not less than eight ounces capacity by weight. 
  • Before refueling a power saw, the refueling spot must be clear of all flammable material, including vegetation. The chainsaw must be restarted only after the operator has moved away from the refueling area. 
  • All power saw operators must stay in the cutting area for one hour after the chainsaw is shut off to watch for fire starts.
Level III

Under IFPL III, personal and commercial woodcutters are prohibited from operating power saws.

 

 

Level IV

Under IFPL IV, personal and commercial woodcutters are prohibited from operating power saws.

 

NOTE: Where hauling involves transit through more than one shutdown/regulated use area, the precaution level at the woods loading site shall govern the level of haul restriction, unless otherwise prohibited by other than the industrial precaution level system.