Skip to Main Content
U.S. Forest Service
Caring for the land and serving people

United States Department of Agriculture

Home > Search > Publication Information

  1. Share via EmailShare on FacebookShare on LinkedInShare on Twitter
    Dislike this pubLike this pub
    Author(s): Luke P. Naeher; Gary L. Achtemeier; Jeff S. Glitzenstein; Donna R. Streng; David Macintosh
    Date: 2006
    Source: Journal of Exposure Science and Environmental Epidemiology: 1-11
    Publication Series: Miscellaneous Publication
    PDF: View PDF  (983 KB)

    Description

    In this study, smoke data were collected from two plots located on the Francis Marion National Forest in South Carolina during prescribed burns on 12 February 2003. One of the plots had been subjected to mechanical chipping, the other was not. This study is part of a larger investigation of fire behavior related to mechanical chipping, parts of which are presented elsewhere. The primary objective of the study reported herein was to measure PM2.5 and CO exposures from prescribed bum smoke from a mechanically chipped vs. non-chipped site. Ground-level time-integrated PM2.5 samplers (n = 9/plot) were placed at a height of 1.5 m around the sampling plots on the downwind side separated by approximately 20 m. Elevated time-integrated PM2.5 samplers (n = 4/plot) were hung atop ~ 30 ft poles at positions within the interior of each of the plots. Real-time PM2.5 and CO data were collected at downwind locations on the perimeter of each plot. Time-integrated perimeter 12-h PM2.5 concentrations in the non-chipped plot (AVG 519.9pg/m3, SD 238.8,ug/m3) were significantly higher (1-tail P-value 0.01) than those at the chipped plot (AVG 198.1 ug/m3, SD 71.6 ,ug/m3). Similarly, interior time-integrated 8-h PM2.5 concentrations in the non-chipped plot (AVG 773.4,ug/m3, SD 321.8,ug/m3) were moderately higher (1-tail P-value 0.06) than those at the chipped plot (AVG 460.3 pg/m3, SD 147.3 ug/m3). Real-time PM2.5 and CO data measured at a position in the chipped plot were uniformly lower than those observed at the same position in the non-chipped plot over the same time period. These results demonstrate that smoke exposures resulting from burned chipped plots are considerably lower than from burned non-chipped plots. These findings have potentially important implications for both firefighters working prescribed burnings at chipped vs. non-chipped sites, as well as nearby communities who may be impacted from smoke traveling downwind from these sights.

    Publication Notes

    • You may send email to pubrequest@fs.fed.us to request a hard copy of this publication.
    • (Please specify exactly which publication you are requesting and your mailing address.)
    • We recommend that you also print this page and attach it to the printout of the article, to retain the full citation information.
    • This article was written and prepared by U.S. Government employees on official time, and is therefore in the public domain.

    Citation

    Naeher, Luke P.; Achtemeier, Gary L.; Glitzenstein, Jeff S.; Streng, Donna R.; Macintosh, David. 2006. Real-time and time-integrated PM2.5 and CO from prescribed burns in chipped and non-chipped plots: firefighter and community exposure and health implications. Journal of Exposure Science and Environmental Epidemiology: 1-11

    Keywords

    prescribed burn, forest fire, firefighter, PM2.5, CO, air quality, mechanical chipping

    Related Search


    XML: View XML
Show More
Show Fewer
Jump to Top of Page
https://www.fs.usda.gov/treesearch/pubs/25612