    Author(s): C. R. Boardman; Samuel V. GlassCharles G. Carll
    Date: 2010
    Source: Thermal performance of the Exterior Envelopes of Whole Buildings XI International Conference, December 5-9, 2010, Clearwater Beach, Florida [electronic resource]. [Atlanta, GA : American Society of Heating, Refrigerating and Air-Conditioning Engineers], 2010. [1 CD-ROM] : 14 p. ISBN 9781933742892
    Publication Series: Miscellaneous Publication
    PDF: View PDF  (616.77 KB)

    Related Research Highlights


    FPL-2015-186
    Understanding Soil Gas Entry Into Homes

    Description

    Proper management of indoor humidity in buildings is an essential aspect of durability. Following dissipation of moisture from construction materials, humidity levels during normal operation are generally assumed to primarily depend on the building volume, the number of building occupants and their behavior, the air exchange rate, and the water vapor content of outdoor air. A potentially large additional source of indoor humidity that often is not considered is the building foundation, which is in contact with earth that commonly damp. Recent work has suggested that the rate of water vapor release from foundations may vary with season, with foundation temperature, and with indoor humidity. This work presents results from a case study of a house with a wood foundation system in which we estimate foundation moisture release given basic interior and exterior conditions, such as relative humidity, temperature, and wind speed. The Alberta air infiltration model was calibrated using tracer gas measurements in the house and used to model air exchange. We use a simplified moisture balance model to estimate the hourly rate of foundation moisture release from the basement. This rate is presented and shown to correlate with stack-driven air exchange for this wood foundation system.

    Publication Notes

    • We recommend that you also print this page and attach it to the printout of the article, to retain the full citation information.
    • This article was written and prepared by U.S. Government employees on official time, and is therefore in the public domain.

    Citation

    Boardman, C. R.; Glass, Samuel V.; Carll, Charles G. 2010. Estimating foundation water vapor release using a simple moisture balance and AIM-2: Case study of a contemporary wood-frame house. In: Thermal performance of the exterior envelopes of whole buildings XI international conference, 2010 December 5-9, Clearwater Beach, Florida [electronic resource]. [Atlanta, GA: American Society of Heating, Refrigerating and Air-Conditioning Engineers]. [1 CD-ROM]: 14 p. ISBN 9781933742892

    Keywords

    Dwellings, heating control, ventilation control, wooden buildings, moisture, building moisture, dwelling moisture, building dampness, humidity control, wooden-frame houses, environmental engineering, testing, wood moisture, building testing, weathering, airtightness, mathematical models, temperature, foundations, water vapor, moisture control, moisture content, durability

    Related Search


    XML: View XML
Show More
Show Fewer
Jump to Top of Page
https://www.fs.usda.gov/treesearch/pubs/37923