Skip to Main Content
U.S. Forest Service
Caring for the land and serving people

United States Department of Agriculture

Home > Search > Publication Information

  1. Share via EmailShare on FacebookShare on LinkedInShare on Twitter
    Dislike this pubLike this pub
    Author(s): Samuel V. GlassCharles G. Carll; Jay P. Curole; Matthew D. Voitier
    Date: 2010
    Source: Thermal performance of the Exterior Envelopes of Whole Buildings XI International Conference, December 5-9, 2010, Clearwater Beach, Florida [electronic resource]. [Atlanta, GA : American Society of Heating, Refrigerating and Air-Conditioning Engineers], 2010: 19 p.: [1 CD-ROM]: 9781933742892.
    Publication Series: Miscellaneous Publication
    PDF: View PDF  (3.59 MB)

    Description

    In flood-prone areas, elevating a building’s floor system above the anticipated flood level can significantly limit the extent of property damage associated with flooding. In hot and humid climates, such as the Gulf Coast region, raised floor systems may, however, be at risk for seasonal moisture accumulation, as the majority of residential buildings in such climates are now mechanically cooled. Conditions were monitored over a one-year period in a sample of 12 houses with insulated raised floors, eight in New Orleans and four in Baton Rouge, Louisiana. Eleven of the 12 houses were located in flood hazard areas and were constructed with open pier foundations. Several types of insulation were compared across the sample of houses. In all houses, crawlspace vapor pressure was essentially the same as outdoor vapor pressure and exceeded indoor vapor pressure from May to October. Moisture conditions within plywood or solid wood subfloors were found to depend on several variables: season, indoor temperature during summer, type of interior floor finish, and type of under-floor insulation. In most cases subfloor moisture levels were higher in summer than in winter. For a given type of insulation and interior floor finish, subfloor moisture content generally increased with decreasing indoor temperature during summer. For a given indoor temperature and type of insulation, subfloor moisture content was generally higher under an impermeable finish, such as vinyl tile, than under a more permeable finish, such as carpet. Floors with foil-faced polyisocyanurate foam board installed below floor joists displayed no discernible seasonal trend in moisture content and little difference between various interior floor finishes. Subfloor moisture readings were consistently in the 10–14% moisture content (MC) range. Floors with closed cell sprayed polyurethane foam showed only a slight seasonal trend and subtle differences between interior floor finishes. Subfloor moisture contents with closed cell foam in all cases were less than 16% MC in plywood and less than 18% MC in solid wood. Clear seasonal trends were observed in floors with open cell foams and with kraft-faced glass fiber batt insulation. Subfloor moisture content readings above 20%, particularly under impermeable interior floor finishes and with low indoor temperatures during the cooling season, suggest that these insulation types do not reliably protect subfloors from seasonal moisture accumulation. For carpeted floors, where subfloor moisture contents were relatively low, application of vapor retarder paint to open cell foam had no discernible effect. In contrast, for floors finished with vinyl, vapor retarder paint applied over open cell foam appeared to result in lower summertime subfloor moisture content, as compared to that for floors insulated with open cell foam without the paint.

    Publication Notes

    • We recommend that you also print this page and attach it to the printout of the article, to retain the full citation information.
    • This article was written and prepared by U.S. Government employees on official time, and is therefore in the public domain.

    Citation

    Glass, Samuel V.; Carll, Charles G.; Curole, Jay P.; Voitier, Matthew D. 2010. Moisture performance of insulated, raised, wood-frame floors: A study of twelve houses in southern Louisiana. In: Thermal performance of the exterior envelopes of whole buildings XI international conference, 2010 December 5-9, Clearwater Beach, FL [electronic resource]. [Atlanta, GA: American Society of Heating, Refrigerating and Air-Conditioning Engineers]: 19 [1 CD-ROM]: 9781933742892.

    Keywords

    Wooden buildings, building moisture, moisture, dwelling moisture, building dampness, wooden-frame houses, environmental engineering, testing, wood moisture, building testing, testing, weathering, foundations, wooden floors, Louisiana, buildings, dwellings, flooding, water vapor pressure, vapor pressure, temperature, humidity, crawl spaces, moisture content, moisture control, durability, raised floors, raised buildings