    Author(s): Charles G. CarllCharles R. Boardman; Collin L. Olson
    Date: 2010
    Source: Thermal performance of the Exterior Envelopes of Whole Buildings XI International Conference, December 5-9, 2010, Clearwater Beach, Florida. [electronic resource] [Atlanta, GA : American Society of Heating, Refrigerating, and Air-Conditioning Engineers], c2010: 17 p. [1 CD-ROM] ISBN: 9781933742892
    Publication Series: Miscellaneous Publication
    PDF: View PDF  (359.93 KB)

    Description

    Performance attributes of a home, constructed in 2001 in Madison, WI, on a treated-wood foundation system were investigated over a multiyear period. Temperature conditions in the basement of the building were, without exception, comfortable, even though the basement was not provided with supply registers for heating or cooling. Basement humidity conditions were acceptable (although not ideal), even though dedicated dehumidification equipment was not used in the building. The basement zone did not develop any perceptible smell of mold. No visible mold growth occurred on surfaces in the basement. After 98 months of building operation, with design humidity levels being maintained during most heating seasons, the foundation system (including cellulose insulation that was below grade) was virtually devoid of visible mold growth. Despite this, moisture contents in the bottom plates of the foundation walls were, at most locations monitored, chronically at or near fiber saturation. Other parts of the foundation remained substantially drier, but apparently at levels roughly in equilibrium with 80% RH. Energy consumption for space heating of the building, normalized to floor area and heating degree days, was roughly equivalent to that for “average” American dwellings constructed between 1990 and 2001. In summary, the moisture performance and thermal performance of the wood foundation system of this building were acceptable.

    Publication Notes

    • We recommend that you also print this page and attach it to the printout of the article, to retain the full citation information.
    • This article was written and prepared by U.S. Government employees on official time, and is therefore in the public domain.

    Citation

    Carll, Charles G.; Boardman, Charles R.; Olson, Collin L. 2010. Case study : performance of a house built on a treated wood foundation system in a cold climate. In: Thermal performance of the Exterior Envelopes of Whole Buildings XI International Conference, December 5-9, 2010, Clearwater Beach, Florida. [electronic resource] [Atlanta, GA : American Society of Heating, Refrigerating, and Air-Conditioning Engineers], c2010: 17 p. [1 CD-ROM] ISBN: 9781933742892

    Keywords

    Architecture, climate, heating, climatic factors, buildings, airtightness, temperature, dampness in buildings, humidity, wooden-frame houses, dwellings, ventilation, wooden buildings, environmental engineering, Wisconsin, moisture, foundations, dampness in basements, energy consumption, case studies, moisture control, wood durability, durability, performance testing, moisture content, moisture content of wood in service