Skip to Main Content
U.S. Forest Service
Caring for the land and serving people

United States Department of Agriculture

Home > Search > Publication Information

  1. Share via EmailShare on FacebookShare on LinkedInShare on Twitter
    Dislike this pubLike this pub
    Author(s): Andrew DeRenzis; Vladimir Kochkin; Xiping Wang
    Date: 2012
    Source: USDA Forest Service, Forest Products Laboratory, General Technical Report, FPL-GTR-214, 2012: 27 p.
    Publication Series: General Technical Report (GTR)
    Station: Forest Products Laboratory
    PDF: View PDF  (1.0 MB)

    Description

    This testing program was designed to benchmark the performance of traditional roof systems and incrementally improved roof-to-wall systems with the goal of developing connection solutions that are optimized for performance and constructability. Nine full-size roof systems were constructed and tested with various levels and types of heel detailing to measure the lateral performance of the roof-to- wall interface. Our test results indicate that the oriented strandboard (OSB) sheathed high-heel truss detail yields performance comparable to that of the unblocked, low-heel truss configuration that is currently allowed by code. Using OSB sheathing as bracing (without any additional blocking in the heel) can be considered an adequate bracing option in high-heel conditions where the intent is to provide structural performance comparable to that of an unblocked, low-heel truss condition. Results also show that extending the OSB sheathing down and including additional nailing to the top plate of the wall below provide strength and stiffness performance superior to that of the solid, intermittent blocking that is currently required in high-wind regions and should be considered a viable truss heel bracing solution to intermittent blocking.

    Publication Notes

    • We recommend that you also print this page and attach it to the printout of the article, to retain the full citation information.
    • This article was written and prepared by U.S. Government employees on official time, and is therefore in the public domain.

    Citation

    DeRenzis, Andrew; Kochkin, Vladimir; Wang, Xiping. 2012. Evaluation of the Lateral Performance of Roof Truss-to-Wall Connections in Light-Frame Wood Systems. USDA Forest Service, Forest Products Laboratory, General Technical Report, FPL-GTR-214, 2012.

    Cited

    Google Scholar

    Keywords

    blocking, lateral performance, low-heel truss, high-heel truss, roof system, roof-to-wall connection

    Related Search


    XML: View XML
Show More
Show Fewer
Jump to Top of Page