Skip to Main Content
U.S. Forest Service
Caring for the land and serving people

United States Department of Agriculture

Home > Search > Publication Information

  1. Share via EmailShare on FacebookShare on LinkedInShare on Twitter
    Dislike this pubLike this pub
    Author(s): F. Holwerda; L.A. Bruijnzeel; F.N. Scatena; H.F. Vugts; A.G.C.A. Meesters
    Date: 2012
    Source: Journal of Hydrology. 414-415: 1-15.
    Publication Series: Scientific Journal (JRNL)
    Station: International Institute of Tropical Forestry
    PDF: View PDF  (1.56 MB)

    Description

    Rainfall interception (I) was measured in 20 m tall Puerto Rican tropical forest with complex topography for a 1-year period using totalizing throughfall (TF) and stemflow (SF) gauges that were measured every 2–3 days. Measured values were then compared to evaporation under saturated canopy conditions (E) determined with the Penman–Monteith (P–M) equation, using (i) measured (eddy covariance) and (ii) calculated (as a function of forest height and wind speed) values for the aerodynamic conductance to momentum flux (ga,M). E was also derived using the energy balance equation and the sensible heat flux measured by a sonic anemometer (Hs). I per sampling occasion was strongly correlated with rainfall (P): I = 0.21P + 0.60 (mm), r2 = 0.82, n = 121. Values for canopy storage capacity (S = 0.37 mm) and the average relative evaporation rate (E/R = 0.20) were derived from data for single events (n = 51). Application of the Gash analytical interception model to 70 multiple-storm sampling events using the above values for S and E/R gave excellent agreement with measured I. For E/R = 0.20 and an average rainfall intensity (R) of 3.16 mm h1, the TF-based E was 0.63 mm h1, about four times the value derived with the P–M equation using a conventionally calculated ga,M (0.16 mm h1). Estimating ga,M using wind data from a nearby but more exposed site yielded a value of E (0.40 mm h1) that was much closer to the observed rate, whereas E derived using the energy balance equation and Hs was very low (0.13 mm h1), presumably because Hs was underestimated due to the use of too short a flux-averaging period (5-min). The best agreement with the observed E was obtained when using the measured ga,M in the P–M equation (0.58 mm h1). The present results show that in areas with complex topography, ga,M, and consequently E, can be strongly underestimated when calculated using equations that were derived originally for use in flat terrain; hence, direct measurement of ga,M using eddy covariance is recommended. The currently measured ga,M (0.31 m s1) was at least several times, and up to one order of magnitude higher than values reported for forests in areas with flat or gentle topography (0.03–0.08 m s1, at wind speeds of about 1 m s1). The importance of ga,M at the study site suggests a negative, downward, sensible heat flux sustains the observed high evaporation rates during rainfall. More work is needed to better quantify Hs during rainfall in tropical forests with complex topography.

    Publication Notes

    • We recommend that you also print this page and attach it to the printout of the article, to retain the full citation information.
    • This article was written and prepared by U.S. Government employees on official time, and is therefore in the public domain.

    Citation

    Holwerda, F.; Bruijnzeel, L.A.; Scatena, F.N.; Vugts, H.F.; Meesters, A.G.C.A. 2012. Wet canopy evaporation from a Puerto Rican lower montane rain forest: the importance of realistically estimated aerodynamic conductance. Journal of Hydrology. 414-415: 1-15.

    Cited

    Google Scholar

    Keywords

    Aerodynamic conductance, Evaporation, Interception, Sensible heat flux, Throughfall, Topography

    Related Search


    XML: View XML
Show More
Show Fewer
Jump to Top of Page
https://www.fs.usda.gov/treesearch/pubs/41633