Smoke Particulate Monitors: 2006 Update

Long Description for Figure 10

Graphic of a graph.
Figure 10—Results comparing an external ac electrical pump to
an internal dc pump on an E-BAM monitor.

This chart compares the test results of the EBAM configured with an external ac-powered pump to the EBAM configured with an internal DC-powered pump. The ac pump EBAM concentrations are on the x-axis. The DC pump EBAM concentrations are on the y-axis. The chart shows the linear regression best fit line. The slope of the line is 1.00.